Tap Water File

OAK RIDGE DEPT OF PUBLIC WORKS

P.O. BOX 1, OAK RIDGE, TN, 37831 · 865-425-1875

On the EPA record

Population served
41614
Service connections
17125
System type
Community water system
Primary water source
Surface water
Owner type
Local government

Drinking-water violations on record (14)

EPA's SDWIS records each violation as codes, not sentences. Each one below is shown with EPA's own published description of that violation type and contaminant. Health-based violations — a contaminant limit or treatment requirement not met — are marked apart from monitoring and reporting failures.

— Other Violation

category Other · monitoring & reporting

Record Keeping — Interim Enhanced Surface Water Treatment Rule

— Other Violation

category Other · monitoring & reporting

Consumer Confidence Report Complete Failure to Report — Consumer Confidence Rule

Recorded as corrected on .

— Treatment Technique Violation

category TT · health-based

Failure Submit Treatment Requirement Rpt — Long Term 2 Enhanced Surface Water Treatment Rule

Recorded as corrected on .

— Monitoring and Reporting

category MR · monitoring & reporting

Monitoring, Regular — Atrazine

Recorded as corrected on .

— Monitoring and Reporting

category MR · monitoring & reporting

Monitoring, Regular — 2,4-D

Recorded as corrected on .

— Monitoring and Reporting

category MR · monitoring & reporting

Monitoring, Routine Minor (TCR) — Coliform (TCR)

Recorded as corrected on .

— Monitoring and Reporting

category MR · monitoring & reporting

Monitoring, Regular — Fluoride

Recorded as corrected on .

— Monitoring and Reporting

category MR · monitoring & reporting

Monitoring, Regular — Nitrate

Recorded as corrected on .

— Monitoring and Reporting

category MR · monitoring & reporting

Monitoring, Regular — Mercury

Recorded as corrected on .

— Monitoring and Reporting

category MR · monitoring & reporting

Monitoring, Regular — Cadmium

Recorded as corrected on .

— Monitoring and Reporting

category MR · monitoring & reporting

Monitoring, Regular — Arsenic

Recorded as corrected on .

— Monitoring and Reporting

category MR · monitoring & reporting

Monitoring, Regular — Barium

Recorded as corrected on .

— Monitoring and Reporting

category MR · monitoring & reporting

Monitoring, Regular — Selenium

Recorded as corrected on .

— Monitoring and Reporting

category MR · monitoring & reporting

Monitoring, Regular — Chromium

Recorded as corrected on .

Source: US Environmental Protection Agency (EPA) · EPA public water system ID (PWSID) TN0000522